Contact Us
Leave Your Message

SZJB200A-D Normally Closed DC Contactor

Lighting control systems are another application area for normally closed DC contactors. In certain lighting applications, these contactors can automatically disconnect the power supply under predetermined conditions, such as when a sensor detects that no one is in the room. This not only improves energy efficiency, but also extends the service life of the lighting equipment.

    FEATURES

    The advantages of using normally closed DC contactors are many and significant. One of the main benefits is safety. By keeping the circuit closed when power is removed, these contactors ensure that the load remains energized, which is particularly important in applications that require continuous power. This feature is essential in environments where equipment must remain operational at all times, such as in critical infrastructure or medical facilities.

    SAYOON MODEL IMPLICATION

    SZJB

    200A

    -D

    -S

    -□

    -□

    /24V

    1

    2

    3

    4

    5

    6

    7

    1

    Product type                

    2

    Rated current                

    3

    Coil type

    4

    Auxiliary switch: None-Without auxiliary switch; S-With auxiliary switch

    5

    Mounting bracket type: None-M Horizontal (default); E-Level embedded; X-Oblique; L(N)-Vertical; E1-Level embedded single direction

    6

    Other function codes

    7

    Coil rated voltage: 6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc

    Uses

    This product have one normally close contact, for electric vehicles, telecommunication equipment, engineering machinery, car batteries, electric forklift trucks, trains, ships, electronic control systems such as uninterruptible power supply.

    Technical Parameters:  (Version 1.75)

     SAYOON Product Type

     SZJB200A-D

     Contact form

     1 NC

     Coil Rated voltage (DC V)

     6V,12V,24V,36V,48V,60V,72V,84V,120V,150V,220V etc.

     Contact voltage (DC V)

     ≤60V

     Rated load current of contact 48V circuit (DC-1)

     200A

     Typical voltage drop across contacts per 100A

     ≤80mV

     The cooling pull-in voltage at (20±5)℃ (V)

     ≤70%

     The cooling drop-out voltage at (20±5)℃ (V)

     ≤35%,≥5%

     Working voltage range of 40℃ coil

     0.8-1.2Us

     Drop-out time (n/o contacts to open)

     10ms

     Pull-in time (n/o contacts to close)

     20ms

     Maximum bounce time for contact connection

     10ms

     Maximum bounce time for contact disconnection

     3ms

     Insulation resistance

     20MΩ

     Electric strength to resist

     50Hz/60Hz 1000VAC 1minute

     Typical fault currents which can be ruptured

     1000A/5ms at 48V/DC

     Coil power (W)

     7-15

     Temperature rise of coil (K)

     ≤80

     Temperature rise on outgoing terminal (K)

     ≤65

     Electrical life

     20,000 times

     Mechanical life

     300,000 times

     Work specification

     Continuous

     Contact material

     Ag alloy

     Load terminal type

     8 Screw

     Coil terminal type

     M4 Screw

     Auxiliary contact rated load (optional)

     2A/48VDC, 5A/24VDC,1NO 1NC

     Testing organization certification

     CE,FCC,RoHS


    Note:As regarding to the different using environments of customers which requires different focus of the functions,and in order to improve the comprehensive properties of our products,sayoon may adjust the coil parameters,temperature rise and so on. The above parameters are for reference only, For details, please refer to the guidelines for selection and use of the SAYOON DC contactor.

    Load Characteristic Curve

    • SEV100AD HV DC Contactor detial (4)
    • SEV100AD HV DC Contactor detial (3)

    Installation Diagram

    szj100a-dszj100a-d-s

    Wiring Diagram

    czw-01_e

    Temperature Curve

    xqws-szj100a-d

    Mechanical Ability And Use Of The Environment

     Contact lead M6 tightening torque (N.m)

     ≯4.5 appropriate

     Coil lead M4 tightening torque (N.m)

     ≯1.2 appropriate

     Ambient temperature

     -25~+70℃

     Relative humidity

     +20℃ 98%

     Vibration freq. atthe fixed position

     3G, 1~50Hz amplitude 0.5mm

     Concussion

     (60~100) time/minute、acceleration≤4g

     Altitude

     2000m

     Installation direction

     Random

     International Protection

     IP40 (According IEC60947)

    Order Instruction

     SAYOON Product Type

     SZJB100A-D

     U.N.W.

     305g

     Package QTY.

     100PCS

     Mounting bracket type

     None - M Horizontal (default), E Level Embedded, L (N) Vertical,E1 Level embedded single direction


    When ordering, please state the following: name, full model, control coil voltage specification, installation frame type, whether with auxiliary contact, order quantity. For example: DC Contactor SZJB100A-D/24V 100pcs, indicating the load rated current 100A, without auxiliary contact, default mounting bracket, coil control voltage 24V purchase 100pcs. Special voltage specification products, such as user needs can be special order.

    certificate

    • CE2
      CCC
    • CCC
      CE
    • RoHS
      RoHS
    • FCC
      ISO9001

    Leave Your Message